OttoMatics Inc. 4313 N. Smoke Ridge Ct. N.E., Roswell, GA 30075
(770) 928-6599 Fax (770) 804-2008

Mangill - Miji Lif 36 Automatic Component Cleaning Unit
Serial Number. 50346 &endash; 1993
 
Currently Configured To Operate Using Water & Non Hazordous Cleaning Solution
Fully Automatic Component Cleaning Machine - Allen Bradley Slc 150 Plc
7 Stage Process - 5 Wash, 2 Dry
Automatic Transfer Between Stages
Mechanical Agitation - Programmable Control Of Vertical Agitation Strokes
5 Wash Stages - 550 Liters (145 Gals) Per Tank
Automatic Monitoring & Adjustment Of Chemical Solution In Wash Stages
2 Drying Stages - Programmable Control Of Drying Cycle
6 Baskets / Stage -Max Load 57kg/Stage-(125lbs)
Stand Alone Mains Water Processing Unit
More 1500 Component Baskets
Qperational requirement
415v, 3 Phase, 50 Hz. 200 Amps
Mains water
Compressed air supply
Vent to outside
Drain
Footprint 11 500mm x 4200mm
 
Two units available.
 
The units in the US should be exactly the same as the one described above. They were described to us as follows:
 
The units are made up of several Miji Lif tanks. The parts ( on baskets) are moved thru the process by a walking beam. When positioned over a tank, the basket is lowered into the liquid (clean or rinse) agitated up & down, raised, then forwarded to the next station. There are heat tunnels at the end, Records indicate that we have S/N 50293 & 50213 at the Old South Miles facility. I cannot find the no's on the equipment to verify they are these exact units..We have ( 2 ) other units also available. One unit is still in a closed mfg facility.
 
Detail as of 2/23/05
 

Mangus

Man-gill
5 Station
With Dryer

 

Unit located nearest the outside wall.
This unit has an Allen Bradley SLC 150 controller.

 

 

 

1. Ultrasonic Generators Missing / Not Functioning.

 

 

 

2. Ultrasonic Transducers Removed.

 

 

 

3. Agitator Roller Removed ( 8/8/01 ).

 

 

 

4. 2 - Nylon Platforms Removed ( 7/3/02 ).

 

 

 

5. 6 - Roller Supports Removed ( 8/7/02 ).

 

 

 

6. 2 - Solenoid Valve Remove ( 9/10/02 ).

 

 

 

7. Grunfus Pump Removed ( 9/10/02 ).

 

 

 

8. 6 - Nylon Guide Blocks ( 10/6/03 ).

 

 

 

9. Items removed from dryer's electrical panel,

 

 

 

 

Mangus

Man-gill
5 station

 

Machine from Kenmore.
This unit has an Allen Bradley SLC 150 controller.

 

 

 

1. No Dryer.

 

 

 

2. No Load Conveyors.

 

 

 

3. Rack Advancement Cylinder Removed.

 

 

 

4. Solenoid Valve on Tank #3 Removed.